Jump to content

Archive:Pile Dynamics Inc.: Difference between revisions

From IdeaWazaWiki
Creation of page for Pile Dynamics that holds several patents in the deep foundation and construction engineering field. The founders were mentioned and a page Dynamic Load Testing which they helped to develop was previous on wikipedia.
 
No edit summary
Line 1: Line 1:
{{Infobox company
| industry = Deep Foundation
Building and Construction
| founded = 1972
| hq_location = Cleveland, Ohio USA
| key_people = Dr. Frank Rausche, Founder
Garland Likins, Founder
Dr. George Goble, Founder
George Piscsalko, P.E., President
| products = Pile Driving Analyzer® (PDA)
Thermal Integrity Profiler (TIPTM)
Shaft Area Profile Evaluator (SHAPE®)
Cross Hole Analyzer (CHAMP‑Q)
Shaft Quantitative Inspection Device (SQUID™)
Pile Integrity Tester (PIT™)
| owner = ESOP Employee Owned
| num_employees = 150
| website = ESOP Employee Owned
}}
Pile Dynamics Inc. (PDI) was established in 1972 by Dr. Frank Rausche with Garland Likins.
Pile Dynamics Inc. (PDI) was established in 1972 by Dr. Frank Rausche with Garland Likins.


The company developed from work done at [[Case Western Reserve University]] (Case),  o''riginally Case Institute of Technology.''
The company developed from work done at Case Western Reserve University (Case)[i]. It began as a research project entitled ''Dynamic Studies on the Bearing Capacity of Piles''<ref>{{Cite web |date=March 1975 |title=Dynamic Studies on the Bearing Capacity of Piles |url=https://onlinepubs.trb.org/Onlinepubs/hrr/1967/167/167-005.pdf}}</ref>. As part of this project several graduate students and faculty conducted research that included Dr. Frank Rausche when he was a student. He was advised by Professors George Goble and Fred Moses. The project entailed using one-dimensional stress wave theory to derive the Case Formula which lead to the invention of the Pile Driving Analyzer® (PDA)<ref>{{Cite web |last=Buck |first=Pile |date=2021-07-26 |title=INTERVIEW: Pile Dynamics, Inc. |url=https://pilebuck.com/interview-pile-dynamics-inc/ |access-date=2025-11-09 |website=Pile Buck Magazine |language=en-US}}</ref>. This device calculates the pile bearing capacity in real time from impact tests on foundation piles.
 
. It began as a research project entitled ''Dynamic Studies on the Bearing Capacity of Piles''<ref>{{Cite web |date=March 1975 |title=Dynamic Studies on the Bearing Capacity of Piles |url=https://onlinepubs.trb.org/Onlinepubs/hrr/1967/167/167-005.pdf}}</ref>. As part of this project several graduate students and faculty conducted research that included Dr. Frank Rausche when he was a student. He was advised by Professors George Goble and Fred Moses. The project entailed using one-dimensional stress wave theory to derive the Case Formula which lead to the invention of the Pile Driving Analyzer® (PDA)<ref>{{Cite web |last=Buck |first=Pile |date=2021-07-26 |title=INTERVIEW: Pile Dynamics, Inc. |url=https://pilebuck.com/interview-pile-dynamics-inc/ |access-date=2025-11-09 |website=Pile Buck Magazine |language=en-US}}</ref>. This device calculates the pile bearing capacity in real time from impact tests on foundation piles.


Likins, another former Case graduate student, further transformed the University prototypes into a routinely usable device and user-friendly software. PDA implemented many new details of dynamic soil modeling and transducer technology and described these efforts in many publications and presentations.  
Likins, another former Case graduate student, further transformed the University prototypes into a routinely usable device and user-friendly software. PDA implemented many new details of dynamic soil modeling and transducer technology and described these efforts in many publications and presentations.  
Line 30: Line 8:


PDI has added other products as it develops additional quality assurance/quality control testing equipment and technologies for the deep foundations industry.
PDI has added other products as it develops additional quality assurance/quality control testing equipment and technologies for the deep foundations industry.
<references />
== Patents ==
* Pile sensing device and method of using the same<ref>{{Cite patent|number=US8382369B2|title=Pile sensing device and method of using the same|gdate=2013-02-26|invent1=Piscsalko|invent2=Rausche|invent3=Cotton|invent4=Ference|inventor1-first=George R.|inventor2-first=Frank|inventor3-first=Dean A.|inventor4-first=Michael|url=https://patents.google.com/patent/US8382369B2/en}}</ref>
* Pile Testing System
* Pile Sensing Device and Method of Using the Same<ref>{{Cite patent|number=US8382369B2|title=Pile sensing device and method of using the same|gdate=2013-02-26|invent1=Piscsalko|invent2=Rausche|invent3=Cotton|invent4=Ference|inventor1-first=George R.|inventor2-first=Frank|inventor3-first=Dean A.|inventor4-first=Michael|url=https://patents.google.com/patent/US8382369B2/en}}</ref>
* Borehole Inspecting and Testing Device and Method of Using the Same<ref>{{Cite patent|number=US20150233230A1|title=Borehole inspecting and testing device and method of using the same|gdate=2015-08-20|invent1=Jr|invent2=Piscsalko|invent3=Rausche|invent4=Cotton|inventor1-first=Garland E. Likins|inventor2-first=George R.|inventor3-first=Frank Frank|inventor4-first=Dean A.|url=https://patents.google.com/patent/US20150233230A1/en}}</ref>
* Borehole Testing Device<ref>{{Cite patent|number=US10330823B2|title=Borehole testing device|gdate=2019-06-25|invent1=Piscsalko|invent2=Cotton|invent3=Jr|invent4=Piedimonte|inventor1-first=George R.|inventor2-first=Dean A.|inventor3-first=Richard E. Berris|inventor4-first=Tyler A.|url=https://patents.google.com/patent/US10330823B2/en}}</ref>
* Non-contact strain measurement system and method for using the same<ref>{{Cite patent|number=MY159657A|title=Pile sensing device and method of using the same|gdate=2017-01-13|invent1=Piscsalko|invent2=Rausche|invent3=Cotton|invent4=Ference|inventor1-first=George R.|inventor2-first=Frank|inventor3-first=Dean A.|inventor4-first=Michael|url=https://patents.google.com/patent/MY159657A/en}}</ref>

Revision as of 17:13, 9 November 2025

Pile Dynamics Inc. (PDI) was established in 1972 by Dr. Frank Rausche with Garland Likins.

The company developed from work done at Case Western Reserve University (Case)[i]. It began as a research project entitled Dynamic Studies on the Bearing Capacity of Piles[1]. As part of this project several graduate students and faculty conducted research that included Dr. Frank Rausche when he was a student. He was advised by Professors George Goble and Fred Moses. The project entailed using one-dimensional stress wave theory to derive the Case Formula which lead to the invention of the Pile Driving Analyzer® (PDA)[2]. This device calculates the pile bearing capacity in real time from impact tests on foundation piles.

Likins, another former Case graduate student, further transformed the University prototypes into a routinely usable device and user-friendly software. PDA implemented many new details of dynamic soil modeling and transducer technology and described these efforts in many publications and presentations.

CAPWAP[3] is a dynamic testing tool with an extensive published correlation study comparing its results favorably with static load tests; as a result CAPWAP is the industry standard in signal matching software. Based on this thorough research and development effort PDI’s dynamic pile testing methods found acceptance around the world.

PDI has added other products as it develops additional quality assurance/quality control testing equipment and technologies for the deep foundations industry.